How to calibrate Schmidt tensiometer


How to calibrate Schmidt tensiometer

Calibration method for Schmitt tensiometer: Calibration with 2-point: When the tension meter is not subjected to any tension, adjust the reading of the tensiometer to 0, and then use a weight equivalent to 80% of the tension measurement (such as a tensiometer) If the measuring range is 10 kg, use a weight of 8 kg or a weight slightly larger than the material tension, hang it under the material to be tested, and then hang the other end of the material to be tested. At this time, the material to be tested is subjected to The tension is the weight of the weight. At this time, the tension value of the tensiometer can be adjusted to the weight of the weight. In this way, the calibration of the tensiometer is completed.
Calibration function of Schmidt Tensiometer: The calibration function of some brands of tension meters on the market is now open, and the calibration function of some brands of tension meters is closed (only manufacturers can use). If the calibration function of the tensiometer is open, if the diameter of the material measured by the customer is different or larger than the calibration diameter of the tension meter when selecting the customer, the customer can calibrate with the material to be tested, and the calibration is very simple. The tension meter from TENSOMETRIC in Germany uses the open calibration mode. If the calibration function of the tensiometer is closed, select the tension timer. The applicable wire diameter range of the tension meter must be small, so the measurement will be correct. If the diameter of the material to be tested is large, you need to order multiple tension meters. Different diameters. Schmitt's (SCHMIDT) tensiometer uses a closed mode of calibration function.

Schmidt Tensiometer Summary: If the calibration function of the tensiometer is open, the customer can select the tension timer, and the main selection is good. If the diameter of the material to be tested is one, the manufacturer can completely leave the factory. Calibrating according to your material diameter is the best choice; if your material is small in diameter and your accuracy requirements are not particularly critical, then the manufacturer can calibrate according to the median diameter of the material.
Humin website: http://
'How does the Schmidt tensiometer calibrate?

Welded Wire Mesh

Welded Wire Mesh,Metal Wire Mesh,Welded Wire Fencing,Industrial Metal Welded Wire

Shenzhou City Hongda Hardware Products Co.,Ltd , https://www.szhdhardware.com